Changes in version 1.2.1
* Fixed error in reading sensor height in LAI-2000 formatted files.
Changes in version 1.2
* Further changes to the Import Dialog to increase flexibility in applying correction factors to imported records. See pages 6-14 and 7-12 in the latest manual (May 2011).
Changes in version 1.0.2
* Added language to the RS-232 Acquire Wizard to make sure the USB connector is not attached while attempting RS-232 downloads.
* Added a checkbox to the Import Dialog that enables applying automatically computed correction factors to the imported records.
Known issues for version 1.0.1
-none-
Known issues for version 1.0.0
* The fields Resp1 and Prompt2 in LAI-2200 files are exchanged each time the file is read. Fixed in 1.0.1.
* When LAI-2000 files (which have no year information in them) are read, their year is set to 2000. This makes it difficult to use as a source for importing records that are closest in time. In version 1.0.1, the year is changed to the current year.